Search results for "Improved method"

showing 10 items of 13 documents

An improved method for evaluating ideal standards in self-perception and mate preferences

2014

The aim of the study was to improve the methodology for measuring ideals of self-perception and mate preferences. The Ideal Standards Model (ISM; Fletcher, Simpson, Thomas & Giles, 1999) was used as a basis for development of the scale. It was further modified by adding a number of items from previous studies. Data were collected from 223 participants, aged 19 to 27 years. The results suggested that a modified five-factor version of the ISM is an appropriate method for evaluation of ideal characteristics. The five factors are warmth/ trustworthiness, status/ resources, intelligence, social skills and physical attractiveness.

AdultMaleIntelligenceSelf-conceptImproved methodTrustSocial classChoice BehaviorSocial SkillsYoung AdultSex FactorsArts and Humanities (miscellaneous)Social skillsDevelopmental and Educational PsychologyHumansMarriageGeneral PsychologyIdeal (set theory)Physical attractivenessGeneral MedicineSelf perceptionSelf ConceptSocial ClassScale (social sciences)FemalePsychologySocial psychologyScandinavian Journal of Psychology
researchProduct

C57BL/6-specific conditions for efficient in utero electroporation of the central nervous system.

2014

Abstract Background In utero electroporation is a fast an efficient tool to specifically address gene expression in the murine central nervous system. This technique was originally established in ICR/CD-1 outbred mice. Neuroanatomical differences between the different mouse strains and variations in gestation length require the optimization of the conditions for each strain to avoid severe complications. Furthermore the relevant position information is currently only scarcely standardized and not always easy to transfer to C57BL/6 mice. New method In this study we present an improved method for in utero electroporation of C57BL/6 including a detailed atlas that allows for specific and effic…

C57BL/6Central Nervous SystemPathologymedicine.medical_specialtyCentral nervous systemGreen Fluorescent ProteinsImproved methodTransfectionAtlases as TopicSpecies SpecificityCell MovementIn vivo transfectionmedicineAnimalsNeuronsMicroscopy ConfocalbiologyGeneral NeuroscienceElectroporationTransfectionbiology.organism_classificationCell biologyMice Inbred C57BLmedicine.anatomical_structureElectroporationIn uteroGestation lengthJournal of neuroscience methods
researchProduct

Methodisches zur bestimmung der molekulargewichtsverteilung von cellulosen

1959

Es wird eine verbesserte Fallungs-Fraktioniermethode zur Ermittlung von Molekulargewichtsverteilungen an Cellulosenitraten beschrieben. Es konnen mit ihr gut reproduzierbare Verteilungskurven erhalten werden, wenn man die notwendigen Bedingungen wie gleichmasige Substitution des Praparates, moglichst kleine Ausgangskonzentration zur Erreichung eines guten Trenneffektes, Vermeidung eines Abbaues wahrend der Fraktionierung usw. in genugender Weise beachtet, – Zur Auswertung der Fraktionierergebnisse raumlich inhomogener Praparate (wie z. B. merzerisierte und oxydativ abgebaute Baumwollen) wird ein statistisches Verfahren vorgeschlagen. An improved method of preciptation fractionation for dete…

ChromatographyChemistryPolymer chemistryImproved methodFractionationDie Makromolekulare Chemie
researchProduct

Determination of -Ascorbic Acid in Lycopersicon Fruits by Capillary Zone Electrophoresis

2001

This study shows an improved method for the determination of L-ascorbic acid (l-AA) in fruits of Lycopersicon by capillary zone electrophoresis (CZE). Two backgrounds electrolytes (BGEs) have been tested: (i) 400 mM borate at pH 8.0 and 1 x 10(-2)% hexadimethrine bromide, for the separation of Eulycopersicon subgenus species; and (ii) as in BGE(i) but supplemented with 20% (v/v) acetonitrile, for the separation of species of the Eriopersicon subgenus. The present procedures were compared with two routine methods-enzymatic assay and potentiometric titration with 2,6-dichlorophenol-indophenol. While these routine methods presented some difficulties in quantifying l-AA in several Lycopersicon …

Detection limitHexadimethrine bromideChromatographybiologyPotentiometric titrationBiophysicsElectrophoresis Capillaryfood and beveragesImproved methodAscorbic AcidCell BiologyAscorbic acidbiology.organism_classificationBiochemistryLycopersiconInternal qualitychemistry.chemical_compoundCapillary electrophoresisSolanum lycopersicumchemistryFruitPotentiometryMolecular BiologyAnalytical Biochemistry
researchProduct

Improved method for cannula fixation for long-term intracerebral brain infusion

2017

Abstract Background Implanted osmotic minipumps are commonly used for long-term, brain-targeted delivery of a wide range of experimental agents by being connected to a catheter and a cannula. During the stereotactical surgery procedure, the cannula has to be placed correctly in the x-y directions and also with respect to the injection point in the z-direction (deepness). However, the flat fixation base of available cannula holders doesn’t allow an easy, secure fixation onto the curve-shaped skull. New method We have developed a modified method for a better fixation of the cannula holder by using an easy-to-produce, skull-shaped silicone spacer as fixation adapter. Results We describe the ap…

Male0301 basic medicinemedicine.medical_specialtySiliconesModified methodImproved methodBrain tissueMice03 medical and health sciencesFixation (surgical)Drug Delivery SystemsImaging Three-Dimensional0302 clinical medicineSurgery procedureSkull surfacemedicineAnimalsCannulabusiness.industryGeneral NeuroscienceBrainInfusion Pumps ImplantableCannulaSurgeryMice Inbred C57BLCatheter030104 developmental biologyTomography X-Ray Computedbusiness030217 neurology & neurosurgeryJournal of Neuroscience Methods
researchProduct

Building large molecular models with plastic screw-on bottle caps and sturdy connectors

2016

An improved method of connecting atoms formed with screw-on bottle caps is described. Fishing line (artificial polymer), steel wire, and countersunk bolts with nyloc nuts are proposed as sturdy connectors. Advantages and disadvantages of each method are described. The molecular models are stable while handling, can be built in a relatively short time at low cost, and can be useful at every level of education. The method is an alternative to professional model kits, in particular in construction of large models for long-term usage.

Materials scienceMolecular modelmolecular modeling05 social sciencesstereochemistry050301 educationMechanical engineeringImproved methodGeneral Chemistry010402 general chemistry01 natural sciencesmolecular properties/structurehands-on learning/manipulativesFishing line0104 chemical sciencesEducationBottle cap0503 educationJournal of Chemical Education
researchProduct

A non-destructive X-ray microtomography approach for measuring fibre length in short-fibre composites

2012

An improved method based on X-ray microtomography is developed for estimating fibre length distribution of short-fibre composite materials. In particular, a new method is proposed for correcting th ...

Materials scienceX-ray microtomographyta114General EngineeringImproved method02 engineering and technology010402 general chemistry021001 nanoscience & nanotechnology01 natural sciences0104 chemical sciencesA fibresNon destructiveMicroscopyCeramics and CompositesLength distributionComposite material0210 nano-technologyta216Composites Science and Technology
researchProduct

Improved method of manufacturing carbon nanotube infused multifunctional 3D woven composites

2021

This research work aimed to develop smart multifunctional composites via a process for uniformly dispersing carbon nanotubes (CNT) on an orthogonal three-dimensional (3D) woven glass fabric with minimised filtering effect. These smart composites could detect strain under tensile and flexural loading by the piezoresistive response of the infused CNT network. Conventional vacuum assisted resin transfer moulding was modified to control the infusion of 0.25 wt% CNT on the 3D woven glass fabric by varying the vacuum pressure. Results showed that at 101.3 kPa vacuum pressure, the CNT percolated through the thickness of the orthogonal 3D woven glass fabric while being marginally filtered by the f…

Materials scienceresin transfer moulding (RTM)Mechanical Engineering3D woven compositeGlass fabricImproved methodCarbon nanotube3D woven composite Carbon nanotubes (CNT) Resin transfer moulding (RTM)law.inventionMechanics of MaterialslawMaterials ChemistryCeramics and Compositescarbon nanotubes (CNT)Composite materialJournal of Composite Materials
researchProduct

Were the chaotic ELMs in TCV the result of an ARMA process?

2004

The results of a previous paper claiming the demonstration that edge localized mode (ELM) dynamics on TCV are chaotic in a number of cases has recently been called into question, because the statistical test employed was found to also identify linear auto regressive—moving average (ARMA) models as chaotic. The TCV ELM data has therefore been re-examined with an improved method that is able to make this distinction, and the ARMA model is found to be an inappropriate description of the dynamics on TCV. The hypothesis that ELM dynamics are chaotic on TCV in a number of cases is therefore still favoured.

Nuclear Energy and EngineeringComputer scienceChaoticImproved methodAutoregressive–moving-average modelArma processStatistical physicsCondensed Matter PhysicsEdge-localized modeStatistical hypothesis testingPlasma Physics and Controlled Fusion
researchProduct

Improved Method for Orbital Elements Differential Correction.

1990

As was pointed out by IAU in 1976, an important problem in fundamental astronomy is the improvement of the vernal equinox and equator positions. To this aim, it is necessary to know the accurate values of minor planets orbital elements. The classical methods of orbital elements differential corrections are based on linking the observations at different epochs considering equal derivatives respect to the initial and osculating elements. In this paper we present an improved method in which the least squares matrix coefficients is calculated from the integration of the Lagrange planetary equations and its derivatives.

Orbital elementsPhysicsEquatorDifferential correctionAstronomyImproved methodEquinoxGeodesyPhysics::History of PhysicsastronomyAsteroidAstrophysics::Earth and Planetary AstrophysicsOrbital correctionDifferential (mathematics)Osculating circle
researchProduct